MP3772 is set to charge Lead Acid batteries by default.
How to set MP3772 for our LiFePo4 Lithium batteries:
- Connect the battery to grey plug on the centre wire (right-most lead supplied with the charger)
- Tap left button 5 times till display reads B1
- Hold down left button till B1 blinks
- Tap middle button to change it to B3
- Hold down left button till B3 stops blinking
Video:
https://bmc.worldmanager.com/go/CVNZxs
Always connect the battery first, and connect the solar panel after the battery is configured.